Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Instrumental validation of free water, peak-width of skeletonized mean diffusivity, and white matter hyperintensities: MarkVCID neuroimaging kits

Producción científica: Article › revisión exhaustiva

98 Citas (Scopus)

Resumen

Introduction: To describe the protocol and findings of the instrumental validation of three imaging-based biomarker kits selected by the MarkVCID consortium: free water (FW) and peak width of skeletonized mean diffusivity (PSMD), both derived from diffusion tensor imaging (DTI), and white matter hyperintensity (WMH) volume derived from fluid attenuation inversion recovery and T1-weighted imaging. Methods: The instrumental validation of imaging-based biomarker kits included inter-rater reliability among participating sites, test–retest repeatability, and inter-scanner reproducibility across three types of magnetic resonance imaging (MRI) scanners using intra-class correlation coefficients (ICC). Results: The three biomarkers demonstrated excellent inter-rater reliability (ICC >0.94, P-values <.001), very high agreement between test and retest sessions (ICC >0.98, P-values <.001), and were extremely consistent across the three scanners (ICC >0.98, P-values <.001). Discussion: The three biomarker kits demonstrated very high inter-rater reliability, test–retest repeatability, and inter-scanner reproducibility, offering robust biomarkers suitable for future multi-site observational studies and clinical trials in the context of vascular cognitive impairment and dementia (VCID).

Idioma originalEnglish
Número de artículoe12261
PublicaciónAlzheimer's and Dementia: Diagnosis, Assessment and Disease Monitoring
Volumen14
N.º1
DOI
EstadoPublished - 2022

Nota bibliográfica

Publisher Copyright:
© 2021 The Authors. Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring published by Wiley Periodicals, LLC on behalf of Alzheimer's Association.

Financiación

U24NS100591; UH3NS100599; UH3NS100588; UH3NS100608; UH3NS100605; UH3NS100606; UH3NS100598; UH3NS100614; P30 AG 010129; 5UH2NS100614-02. The authors thank: Bruce Fischl, Department of Radiology, Massachusetts General Hospital; Arnold M. Evia, Rush Alzheimer's Disease Center, Rush University Medical Center and Nazanin Makkinejad, Department of Biomedical Engineering, Illinois Institute of Technology; Xin Li and Yang Li, Department of Radiology, Johns Hopkins University School of Medicine; Samantha Ma, Departments of Neurology and Radiology, Keck School of Medicine, University of Southern California; Elyas Fadaee, Glenn Biggs Institute for Alzheimer's and Neurodegenerative Diseases, University of Texas Health San Antonio; Andrew Warren, Mitchell Horn, and Vanessa Gonzalez, Department of Neurology, Massachusetts General Hospital; and Linda McGavern from NIH/NINDS.

Financiadores
Department of Biomedical Engineering
Neurology Department
Elyas Fadaee
Glenn Biggs Institute for Alzheimer's and Neurodegenerative Diseases, University of Texas Health San Antonio
National Institutes of Health, National Institutes of Health
Institute of Neurological Disorders and Stroke National Advisory Neurological Disorders and Stroke Council
Massachusetts General Hospital
University of Southern California
Johns Hopkins University School of Medicine
Illinois Institute of Technology
Department of Radiology, Weill Cornell Medical College

    ODS de las Naciones Unidas

    Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

    1. Good health and well being
      Good health and well being

    ASJC Scopus subject areas

    • Clinical Neurology
    • Psychiatry and Mental health

    Huella

    Profundice en los temas de investigación de 'Instrumental validation of free water, peak-width of skeletonized mean diffusivity, and white matter hyperintensities: MarkVCID neuroimaging kits'. En conjunto forman una huella única.

    Citar esto