Interoperator reliability of an on-site machine learning-based prototype to estimate CT angiography-derived fractional flow reserve

  • Yushui Han
  • , Ahmed Ibrahim Ahmed
  • , Chris Schwemmer
  • , Myra Cocker
  • , Talal S. Alnabelsi
  • , Jean Michel Saad
  • , Juan C.Ramirez Giraldo
  • , Mouaz H. Al-Mallah

Producción científica: Articlerevisión exhaustiva

3 Citas (Scopus)

Resumen

Background Advances in CT and machine learning have enabled on-site non-invasive assessment of fractional flow reserve (FFR CT). Purpose To assess the interoperator and intraoperator variability of coronary CT angiography-derived FFR CT using a machine learning-based postprocessing prototype. Materials and methods We included 60 symptomatic patients who underwent coronary CT angiography. FFR CT was calculated by two independent operators after training using a machine learning-based on-site prototype. FFR CT was measured 1 cm distal to the coronary plaque or in the middle of the segments if no coronary lesions were present. Intraclass correlation coefficient (ICC) and Bland-Altman analysis were used to evaluate interoperator variability effect in FFR CT estimates. Sensitivity analysis was done by cardiac risk factors, degree of stenosis and image quality. Results A total of 535 coronary segments in 60 patients were assessed. The overall ICC was 0.986 per patient (95% CI 0.977 to 0.992) and 0.972 per segment (95% CI 0.967 to 0.977). The absolute mean difference in FFR CT estimates was 0.012 per patient (95% CI for limits of agreement: -0.035 to 0.039) and 0.02 per segment (95% CI for limits of agreement: -0.077 to 0.080). Tight limits of agreement were seen on Bland-Altman analysis. Distal segments had greater variability compared with proximal/mid segments (absolute mean difference 0.011 vs 0.025, p<0.001). Results were similar on sensitivity analysis. Conclusion A high degree of interoperator and intraoperator reproducibility can be achieved by on-site machine learning-based FFR CT assessment. Future research is required to evaluate the physiological relevance and prognostic value of FFR CT.

Idioma originalEnglish
Número de artículoe001951
PublicaciónOpen Heart
Volumen9
N.º1
DOI
EstadoPublished - mar 21 2022

Nota bibliográfica