Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Mass transfer in hollow fiber membrane contactor extraction using compressed solvents

Producción científica: Articlerevisión exhaustiva

41 Citas (Scopus)

Resumen

Ethanol and acetone were extracted from aqueous feed streams (10wt.% solute) at ambient temperature using compressed propane (34.5bar) and CO 2 (69bar) in a polypropylene hollow fiber membrane contactor (HFC). Overall mass transfer coefficients were determined and related to tubeside, membrane, and shellside mass transfer by varying the aqueous velocity (0.6-11.8cm/s) and molar solvent to feed ratio (1 to 3) in countercurrent flow. The overall mass transfer coefficient for ethanol and acetone extraction with compressed propane ranged from 3.8×10-4 to 1.1×10 -2 and 1.1×10-4 to 1.7×10-3cm/s, respectively. For compressed CO2, the overall mass transfer coefficient ranged from 5.1×10-4 to 1.4×10 -3cm/s for ethanol extraction and 4.1×10-4 to 9.5×10-4cm/s for acetone extraction. Experimentally determined shellside mass transfer coefficients were compared to values predicted by existing correlations for HFC extraction with non-pressurized solvents. Enhanced HFC mass transfer is observed with compressed solvents relative to both conventional liquid HFC extraction and to column extraction with compressed CO2. Our results demonstrate the applicability of compressed hydrocarbons to HFC-based processes, and the ability to analyze compressed solvent-based extraction using conventional HFC techniques.

Idioma originalEnglish
Páginas (desde-hasta)183-196
Número de páginas14
PublicaciónJournal of Membrane Science
Volumen227
N.º1-2
DOI
EstadoPublished - dic 15 2003

Nota bibliográfica

Funding Information:
The authors acknowledge the financial support of the National Science Foundation (Grant BES-9817069), and Marc Sims at Porocrit™ for providing the single fiber units and assistance with the initial design of the system. We also acknowledge the advice of Alan Gabelman, Dr. Bill Krantz, and Dr. Sun-Tak Hwang at the Center for Membrane Applied Science and Technology located at the University of Cincinnati, and Dr. Esteban Brignole (PLAPIQUI, Bahı́a Blanca, Argentina) for his invaluable contributions.

Financiación

The authors acknowledge the financial support of the National Science Foundation (Grant BES-9817069), and Marc Sims at Porocrit™ for providing the single fiber units and assistance with the initial design of the system. We also acknowledge the advice of Alan Gabelman, Dr. Bill Krantz, and Dr. Sun-Tak Hwang at the Center for Membrane Applied Science and Technology located at the University of Cincinnati, and Dr. Esteban Brignole (PLAPIQUI, Bahı́a Blanca, Argentina) for his invaluable contributions.

FinanciadoresNúmero del financiador
National Science Foundation (NSF)BES-9817069

    ASJC Scopus subject areas

    • Biochemistry
    • General Materials Science
    • Physical and Theoretical Chemistry
    • Filtration and Separation

    Huella

    Profundice en los temas de investigación de 'Mass transfer in hollow fiber membrane contactor extraction using compressed solvents'. En conjunto forman una huella única.

    Citar esto