Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

On the use of single-isocenter VMAT plans for SBRT treatment of synchronous multiple lung lesions: Plan quality, treatment efficiency, and early clinical outcomes

Producción científica: Article › revisión exhaustiva

11 Citas (Scopus)

Resumen

Cone-beam computed tomography (CT)-guided volumetric-modulated arc therapy (VMAT) plans for stereotactic body radiotherapy (SBRT) treatment of synchronous multiple lung lesions with a flattening filter-free (FFF) beam is a safe and highly effective treatment option for oligometastases lung cancer patients. Fourteen patients with metastatic non–small-cell lung cancer (NSCLC) lesions (two to five) received a single-isocenter VMAT SBRT treatment in our clinic. Four-dimensional (4D) CT-based treatment plans were generated using advanced AcurosXB-based dose calculation algorithm using heterogeneity corrections with a single isocenter placed between/among the lesions. Compared to 10X-FFF and traditional flattened 6X (6X-FF) beams, 6X-FFF beam produced highly conformal radiosurgical dose distribution to each target volume, reduced dose to adjacent organs at risk (OAR), and significantly reduced the lung SBRT fraction duration to < 3.5 min/fraction for 54/50 Gy treatments in 3/5 fractions — significantly improving patient convenience and clinic workflow. Early follow-up CT imaging (mean, 9 months) results show high local control rates (100%) with no acute lung or rib toxicity. Longer clinical follow up in a larger patient cohort is ongoing to further validate the outcomes of this treatment approach.

Idioma originalEnglish
Páginas (desde-hasta)160-167
Número de páginas8
PublicaciónJournal of Applied Clinical Medical Physics
Volumen21
N.º8
DOI
EstadoPublished - ago 1 2020

Nota bibliográfica

Publisher Copyright:
© 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. Good health and well being
    Good health and well being

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Huella

Profundice en los temas de investigación de 'On the use of single-isocenter VMAT plans for SBRT treatment of synchronous multiple lung lesions: Plan quality, treatment efficiency, and early clinical outcomes'. En conjunto forman una huella única.

Citar esto