Operation of an opamp at liquid helium temperature.

Producción científica: Articlerevisión exhaustiva

5 Citas (Scopus)

Resumen

The stray capacitance between long wires in a cryogenics systems will slow down measurement rate, and also introduce unnecessary noise pick up. It is necessary to install the preamplifier as close to the signal source as possible to diminish the capacitive coupling effects. The most commonly used semiconducting device for this purpose is the MOSFET, which can function at liquid helium temperatures. Under special operation procedures, an all MOSFET operational amplifier can also be operated at liquid helium temperature. The use of opamp will simplify the construction of more complicated circuitry for low temperature applications.