TY - JOUR
T1 - Ozone-induced respiratory illness during the repair of a portland cement kiln
AU - Sanderson, Wayne T.
AU - Almaguer, Daniel
AU - Kirk, L. Harvey
PY - 1999
Y1 - 1999
N2 - Objectives. Workers at a portland cement plant had experienced acute respiratory and eye irritation when performing maintenance inside a kiln. These episodes were associated with a bleach-like odor, which was only reported during maintenance operations. An industrial hygiene investigation was conducted to determine the cause of the illness. Methods. While workers replaced refractory brick inside the kiln, air samples were collected for chlorine, sulfur dioxide, inorganic acid, ozone, and dust. After the rebricking was completed and all the workers had exited the kiln, its electrostatic precipitator was reduced to half power and the induced-draft (ID) fan was turned off to recreate conditions present during illness episodes. Results. Chlorine, inorganic acid, and ozone were not detected, and only trace concentrations of sulfur dioxide were detected while workers were inside the kiln. However, when conditions present during previous episodes were recreated, the bleach-like odor was soon evident. Chlorine was not detected, but 0.09 to 0.11 ppm of ozone was measured at the discharge end of the kiln, and 4.5 ppm was measured at the inlet end. Within a half hour after the electrostatic precipitator was turned off and the ID fan was turned on, the ozone concentrations decreased to background levels of 0.02-0.03 ppm. Conclusions. Somewhat lower ozone exposures may have occurred during previous kiln maintenance operations due to more open access portals, but previous episodes of eye and respiratory imitation were probably caused when ozone, generated by the electrostatic precipitator, back-drafted into the kiln after the ID fan was turned off.
AB - Objectives. Workers at a portland cement plant had experienced acute respiratory and eye irritation when performing maintenance inside a kiln. These episodes were associated with a bleach-like odor, which was only reported during maintenance operations. An industrial hygiene investigation was conducted to determine the cause of the illness. Methods. While workers replaced refractory brick inside the kiln, air samples were collected for chlorine, sulfur dioxide, inorganic acid, ozone, and dust. After the rebricking was completed and all the workers had exited the kiln, its electrostatic precipitator was reduced to half power and the induced-draft (ID) fan was turned off to recreate conditions present during illness episodes. Results. Chlorine, inorganic acid, and ozone were not detected, and only trace concentrations of sulfur dioxide were detected while workers were inside the kiln. However, when conditions present during previous episodes were recreated, the bleach-like odor was soon evident. Chlorine was not detected, but 0.09 to 0.11 ppm of ozone was measured at the discharge end of the kiln, and 4.5 ppm was measured at the inlet end. Within a half hour after the electrostatic precipitator was turned off and the ID fan was turned on, the ozone concentrations decreased to background levels of 0.02-0.03 ppm. Conclusions. Somewhat lower ozone exposures may have occurred during previous kiln maintenance operations due to more open access portals, but previous episodes of eye and respiratory imitation were probably caused when ozone, generated by the electrostatic precipitator, back-drafted into the kiln after the ID fan was turned off.
KW - Electrostatic precipitator
KW - Eye irritation
KW - Kiln maintenance
KW - Ozone
KW - Respiratory irritation
KW - SIC 3241 (portland cement manufacturing)
UR - http://www.scopus.com/inward/record.url?scp=0032767942&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032767942&partnerID=8YFLogxK
U2 - 10.5271/sjweh.428
DO - 10.5271/sjweh.428
M3 - Article
C2 - 10450773
AN - SCOPUS:0032767942
SN - 0355-3140
VL - 25
SP - 227
EP - 232
JO - Scandinavian Journal of Work, Environment and Health
JF - Scandinavian Journal of Work, Environment and Health
IS - 3
ER -