Resumen
Context: The SMART™ software system offers low-cost kinematic analysis through digitization of video from a single camera. The reliability and validity of this product have not been reported. Objective: To assess the reliability and validity of the SMART software during a simple static task and dynamic task. Design: Test-retest to compare assumed neutral and goniometrically measured joint angles in the sagittal plane of the lower extremity. Setting: Research laboratory. Participants: 7 in a static task, 16 young, physically active in a dynamic task. Results: Measurement error of the SMART system ranged from 0.29° ± 1.98° to 11.07° ± 1.77°. The interrater reliability (ICC2,1) values ranged from .60 to .92 for the static task and from .76 to .89 for the dynamic task. Conclusions: Based on the results of both studies, the SMART system offers a low-cost alternative for reporting single-plane kinematics during an individual frame of video during static stances and slow dynamic tasks with strong reliability and reasonable validity.
| Idioma original | English |
|---|---|
| Páginas (desde-hasta) | 137-149 |
| Número de páginas | 13 |
| Publicación | Journal of Sport Rehabilitation |
| Volumen | 14 |
| N.º | 2 |
| DOI | |
| Estado | Published - may 2005 |
ASJC Scopus subject areas
- Biophysics
- Orthopedics and Sports Medicine
- Physical Therapy, Sports Therapy and Rehabilitation
- Rehabilitation
Huella
Profundice en los temas de investigación de 'Reliability and validity of a 2-D video digitizing system during a static and a dynamic task'. En conjunto forman una huella única.Citar esto
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver