TY - JOUR
T1 - SLControl
T2 - PC-based data acquisition and analysis for muscle mechanics
AU - Campbell, Kenneth S.
AU - Moss, Richard L.
PY - 2003/12
Y1 - 2003/12
N2 - SLControl is a computerized data acquisition and analysis system that was developed in our laboratory to help perform mechanical experiments using striated muscle preparations. It consists of a computer program (Windows 2000 or later) and a commercially available data acquisition board (16-bit resolution, DAP5216a, Microstar Laboratories, Bellevue, WA). Signals from the user's existing equipment representing force, fiber length (FL), and (if desired) sarcomere length (SL) are connected to the system through standard Bayonet Neill Concelman cables and saved to data files for later analysis. Output signals from the board control FL and trigger additional equipment, e.g., flash lamps. Windows dialogs drive several different experimental protocols, including slack tests and rate of tension recovery measurements. Precise measurements of muscle stiffness and force velocity/power characteristics can also be accomplished using SL and tension control, respectively. In these situations, the FL command signal is updated in real time (at rates ≥2.5 kHz) in response to changes in the measured SL or force signals. Data files can be exported as raw text or analyzed within SLControl with the use of built-in tools for cursor analysis, digital filtering, curve fitting, etc. The software is available for free download at http://www.slcontrol.com.
AB - SLControl is a computerized data acquisition and analysis system that was developed in our laboratory to help perform mechanical experiments using striated muscle preparations. It consists of a computer program (Windows 2000 or later) and a commercially available data acquisition board (16-bit resolution, DAP5216a, Microstar Laboratories, Bellevue, WA). Signals from the user's existing equipment representing force, fiber length (FL), and (if desired) sarcomere length (SL) are connected to the system through standard Bayonet Neill Concelman cables and saved to data files for later analysis. Output signals from the board control FL and trigger additional equipment, e.g., flash lamps. Windows dialogs drive several different experimental protocols, including slack tests and rate of tension recovery measurements. Precise measurements of muscle stiffness and force velocity/power characteristics can also be accomplished using SL and tension control, respectively. In these situations, the FL command signal is updated in real time (at rates ≥2.5 kHz) in response to changes in the measured SL or force signals. Data files can be exported as raw text or analyzed within SLControl with the use of built-in tools for cursor analysis, digital filtering, curve fitting, etc. The software is available for free download at http://www.slcontrol.com.
KW - Instrumentation
KW - Real-time control
KW - Sarcomere length measurement
UR - https://www.scopus.com/pages/publications/0344440709
UR - https://www.scopus.com/pages/publications/0344440709#tab=citedBy
U2 - 10.1152/ajpheart.00295.2003
DO - 10.1152/ajpheart.00295.2003
M3 - Article
C2 - 12907419
AN - SCOPUS:0344440709
SN - 0363-6135
VL - 285
SP - H2857-H2864
JO - American Journal of Physiology - Heart and Circulatory Physiology
JF - American Journal of Physiology - Heart and Circulatory Physiology
IS - 6 54-6
ER -