Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Squeeze me if you can: Variability in force requirements to extract a drop from common glaucoma bottles

Producción científica: Articlerevisión exhaustiva

21 Citas (Scopus)

Resumen

Purpose: To determine the force requirements to dispense a single drop from commonly prescribed brand and generic topical glaucoma medications and correlate these findings with pinch strength in a representative patient population. Patients and Methods: Four bottles of each medication were tested: 2 in the vertical and 2 in the horizontal orientation. Bottles were housed in a customized force gauge apparatus designed to mimic ballpoint fingertip contact with a bottle tip. For all bottles, each of the first 10 dispensed drops was tested and then tests were performed in increments of 10 until the bottle was empty. For each tested drop, the maximum force and displacement were electronically measured. Concurrently, maximum pinch strength was measured on consecutive glaucoma patients. Results: A total of 84 bottles from 21 bottle designs were tested. There was significant variability across the designs, with roughly a 7-fold (0.67 to 4.49 kgf) and 4-fold (0.81 to 3.00 kgf) difference in force requirements in the vertical and horizontal positions, respectively. Of 53 enrolled patients in the glaucoma clinic, the mean pinch strength was 5.05 (range, 1.23 to 10.4 kgf) and 4.82 (range, 1.47 to 10.67 kgf) kgf for the right and left hands, respectively. Conclusions: There is statistically significant variability in the force required to squeeze a drop from common glaucoma medications, and a representative sampling of clinic patients suggests that many likely struggle with the force requirements of several bottle designs. These data further support standardization of topical glaucoma drug delivery and design.

Idioma originalEnglish
Páginas (desde-hasta)780-784
Número de páginas5
PublicaciónJournal of Glaucoma
Volumen25
N.º9
DOI
EstadoPublished - 2016

Nota bibliográfica

Publisher Copyright:
© 2016 Wolters Kluwer Health, Inc.

Financiación

Supported by the National Center for Research Resources and the National Center for Advancing Translational Sciences, National Institutes of Health, through Grant UL1TR000117.

FinanciadoresNúmero del financiador
National Institutes of Health (NIH)
National Center for Research Resources
National Center for Advancing Translational Sciences (NCATS)UL1TR000117