Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Static Cage Morphology in Short-Segment Transforaminal Lumbar Interbody Fusions Is Associated With Alterations in Foraminal Height But Not Clinical Outcomes

  • Nathaniel Toop
  • , Andrew Grossbach
  • , David Gibbs
  • , Asad Akhter
  • , Alexander Keister
  • , Dominic Maggio
  • , James Oosten
  • , Kyle Deistler
  • , Ty Gilkey
  • , H. Francis Farhadi
  • , Stephanus Viljoen

Producción científica: Articlerevisión exhaustiva

4 Citas (Scopus)

Resumen

Introduction: Steerable “banana” cages have been posited to increase segmental lordosis in short-segment transforaminal lumbar interbody fusions (TLIF). The same is not necessarily true for straight “bullet” cages. Although increased lordosis is generally thought to be advantageous, a potential complication is decreased foraminal height. Here we evaluate for any association between cage type and change in foraminal height and clinical outcomes following short-segment TLIFs. Methods: We retrospectively reviewed consecutive 1- and 2-level TLIFs with bilateral facetectomies with minimum 1-year clinical and radiographic follow-up. Two cohorts were based on cage morphology: steerable “banana” cage or straight “bullet” cage. Patient reported outcome measures (PROMs), radiographic measurements, and revision rates were compared. Results: A total of 46 patients with 53 straight and 95 patients with 131 steerable cage levels were included. Steerable cages showed increased segmental lordosis (9.1° vs. 13.5°, P < 0.001) and decreased foraminal height (20.3 vs. 18.5 mm, P < 0.001) after surgery. Straight cages demonstrated similar segmental lordosis (8.7° vs 8.1°, P = 0.30) and foraminal height (19.4 vs 20.0 mm, P < 0.065). Both cohorts showed improved PROMs at last follow-up (P ≤ 0.005). Subanalysis comparing patients who had increased or decreased foraminal height revealed similarly improved PROMs between cohorts. Revision rates at 1 year were similar between cohorts (4.3% for straight and 3.2% for steerable group, P = 0.72). Conclusions: Although the increased segmental lordosis afforded by placement of steerable cages may decrease foraminal height after short segment TLIF, clinical outcomes are not negatively affected by this association.

Idioma originalEnglish
Páginas (desde-hasta)e389-e398
PublicaciónWorld Neurosurgery
Volumen159
DOI
EstadoPublished - mar 2022

Nota bibliográfica

Publisher Copyright:
© 2021 Elsevier Inc.

Financiación

Conflict of interest statement: H.F. Farhadi: Research funding from DePuy, Nexxt Spine, and Implanet America; A. Grossbach: Research funding from DePuy, Medtronic, 3M/KCI; consultation fees from 3M/KCI; S. Viljoen: Research funding from Medtronic.

Financiadores
Nexxt Spine
Medtronic

    ASJC Scopus subject areas

    • Surgery
    • Clinical Neurology

    Huella

    Profundice en los temas de investigación de 'Static Cage Morphology in Short-Segment Transforaminal Lumbar Interbody Fusions Is Associated With Alterations in Foraminal Height But Not Clinical Outcomes'. En conjunto forman una huella única.

    Citar esto