Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Systematic review and meta-analysis of valve-in-valve transcatheter aortic valve replacement in patients with failed bioprosthetic aortic valves

  • Ahmed N. Mahmoud
  • , Mohamed M. Gad
  • , Islam Y. Elgendy
  • , Ahmad A. Mahmoud
  • , Yasmeen Taha
  • , Akram Y. Elgendy
  • , Keerat R. Ahuja
  • , Anas M. Saad
  • , Matheus Simonato
  • , James M. McCabe
  • , Mark Reisman
  • , Samir R. Kapadia
  • , Danny Dvir

Producción científica: Review articlerevisión exhaustiva

22 Citas (Scopus)

Resumen

Aims: The aim of this meta-analysis was to evaluate the evidence regarding the rates of procedural success and the incidence of adverse outcomes following valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) in patients with failed bioprosthetic aortic valves. Methods and results: A systematic search of major electronic databases was conducted for studies relevant to patients with failed bioprosthetic aortic valves undergoing VIV-TAVR. The primary outcome was procedural success. A total of 5,553 patients from 24 studies were included. The mean Society of Thoracic Surgeons (STS) score was 7.84±5.14. The procedural success rate was high (97%, 95% confidence interval [CI]: 94-98%). At 30 days, all-cause mortality was 5% (95% CI: 3-6%), stroke 2% (95% CI: 1-2%), myocardial infarction 1% (95% CI: 1-2%), permanent pacemaker placement 6% (95% CI: 5-8%), and aortic regurgitation 7% (95% CI: 5-10%). At one year, the incidence of all-cause mortality was 12% (95% CI: 10-14%), stroke 3% (95% CI: 2-4%), myocardial infarction 1% (95% CI: 0-2%), and permanent pacemaker placement 7% (95% CI: 5-11%). At three years, the incidence of all-cause mortality was 29% (95% CI: 25-34%) and stroke 6% (95% CI: 5-9%). Conclusions: VIV-TAVR appears to be associated with high procedural success rates and low adverse outcomes during the short-term and midterm follow-up period.

Idioma originalEnglish
Páginas (desde-hasta)539-548
Número de páginas10
PublicaciónEuroIntervention
Volumen16
N.º7
DOI
EstadoPublished - 2021

Nota bibliográfica

Publisher Copyright:
© Europa Digital & Publishing 2020. All rights reserved.

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Huella

Profundice en los temas de investigación de 'Systematic review and meta-analysis of valve-in-valve transcatheter aortic valve replacement in patients with failed bioprosthetic aortic valves'. En conjunto forman una huella única.

Citar esto