Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

The ankle–brachial index, gastrocnemius mitochondrial respirometry, and walking performance in people with and without peripheral artery disease

  • Mary M. McDermott
  • , Sudarshan Dayanidhi
  • , Christiaan Leeuwenburgh
  • , Stephanie E. Wohlgemuth
  • , Luigi Ferrucci
  • , Charlotte A. Peterson
  • , Lu Tian
  • , Robert Sufit
  • , Lihui Zhao
  • , Joshua Slysz
  • , Tamar S. Polonsky
  • , Jack M. Guralnik
  • , Melina R. Kibbe
  • , Karen J. Ho
  • , Michael H. Criqui
  • , Dongxue Zhang
  • , Shujun Xu
  • , Philip Greenland

Producción científica: Articlerevisión exhaustiva

Resumen

Background: Mitochondrial abnormalities exist in lower-extremity peripheral artery disease (PAD), yet the association of the ankle–brachial index (ABI) with mitochondrial respiration in gastrocnemius muscle is unknown. The association of gastrocnemius mitochondrial respiration with 6-minute walk distance in PAD is unknown. This objective of this study was to describe associations of the ABI with mitochondrial respiratory function in gastrocnemius muscle biopsies and associations of gastrocnemius mitochondrial respirometry with 6-minute walk distance in people with and without PAD. Methods: People with (ABI ⩽ 0.90) and without (ABI 1.00–1.40) PAD were enrolled. ABI and 6-minute walk distance were measured. Mitochondrial function of permeabilized myofibers from gastrocnemius biopsies was measured with high-resolution respirometry. Results: A total of 30 people with PAD (71.7 years, mean ABI: 0.64) and 68 without PAD (71.8 years, ABI: 1.17) participated. In non-PAD participants, higher ABI values were associated significantly with better mitochondrial respiration (Pearson correlation for maximal oxidative phosphorylation PCI+II: +0.29, p = 0.016). In PAD, the ABI correlated negatively and not significantly with mitochondrial respiration (Pearson correlation for PCI+II: –0.17, p = 0.38). In people without PAD, better mitochondrial respiration was associated with better 6-minute walk distance (Pearson correlation: +0.51, p < 0.001), but this association was not present in PAD (Pearson correlation: +0.10, p = 0.59). Conclusions: Major differences exist between people with and without PAD in the association of gastrocnemius mitochondrial respiration with ABI and 6-minute walk distance. Among people without PAD, ABI and walking performance were positively associated with mitochondrial respiratory function. These associations were not observed in PAD.

Idioma originalEnglish
Páginas (desde-hasta)640-652
Número de páginas13
PublicaciónVascular Medicine (United Kingdom)
Volumen29
N.º6
DOI
EstadoPublished - dic 2024

Nota bibliográfica

Publisher Copyright:
© The Author(s) 2024.

Financiación

This study was supported by the American Heart Association (18SFRN33900142, 18SFRN33900097, 18SFRN33900136, 18SFRN3390010).

FinanciadoresNúmero del financiador
American the American Heart Association18SFRN3390010, 18SFRN33900136, 18SFRN33900142, 18SFRN33900097
American the American Heart Association

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine

    Huella

    Profundice en los temas de investigación de 'The ankle–brachial index, gastrocnemius mitochondrial respirometry, and walking performance in people with and without peripheral artery disease'. En conjunto forman una huella única.

    Citar esto