The effect of tandem-ovoid titanium applicator on points A, B, bladder, and rectum doses in gynecological brachytherapy using 192Ir

  • Mohammad Hosein Sadeghic
  • , Sedigheh Sina
  • , Amir Mehdizadeh
  • , Reza Faghihi
  • , Vahed Moharramzadeh
  • , Ali Soleimani Meigooni

Producción científica: Articlerevisión exhaustiva

3 Citas (Scopus)

Resumen

Purpose: The dosimetry procedure by simple superposition accounts only for the self-shielding of the source and does not take into account the attenuation of photons by the applicators. The purpose of this investigation is an estimation of the effects of the tandem and ovoid applicator on dose distribution inside the phantom by MCNP5 Monte Carlo simulations. Material and methods: In this study, the superposition method is used for obtaining the dose distribution in the phantom without using the applicator for a typical gynecological brachytherapy (superposition-1). Then, the sources are simulated inside the tandem and ovoid applicator to identify the effect of applicator attenuation (superposition-2), and the dose at points A, B, bladder, and rectum were compared with the results of superposition. The exact dwell positions, times of the source, and positions of the dosimetry points were determined in images of a patient and treatment data of an adult woman patient from a cancer center. The MCNP5 Monte Carlo (MC) code was used for simulation of the phantoms, applicators, and the sources. Results: The results of this study showed no significant differences between the results of superposition method and the MC simulations for different dosimetry points. The difference in all important dosimetry points was found to be less than 5%. Conclusions: According to the results, applicator attenuation has no significant effect on the calculated points dose, the superposition method, adding the dose of each source obtained by the MC simulation, can estimate the dose to points A, B, bladder, and rectum with good accuracy.

Idioma originalEnglish
Páginas (desde-hasta)91-95
Número de páginas5
PublicaciónJournal of Contemporary Brachytherapy
Volumen10
N.º1
DOI
EstadoPublished - 2018

Nota bibliográfica

Publisher Copyright:
© J Contemp Brachytherapy 2018.

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. Good health and well being
    Good health and well being

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Huella

Profundice en los temas de investigación de 'The effect of tandem-ovoid titanium applicator on points A, B, bladder, and rectum doses in gynecological brachytherapy using 192Ir'. En conjunto forman una huella única.

Citar esto