Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Three-dimensional vapor intrusion modeling approach that combines wind and stack effects on indoor, atmospheric, and subsurface domains

Producción científica: Articlerevisión exhaustiva

22 Citas (Scopus)

Resumen

Vapor intrusion (IV) exposure risks are difficult to characterize due to the role of atmospheric, building and subsurface processes. This study presents a three-dimensional VI model that extends the common subsurface fate and transport equations to incorporate wind and stack effects on indoor air pressure, building air exchange rate (AER) and indoor contaminant concentration to improve VI exposure risk estimates. The model incorporates three modeling programs: (1) COMSOL Multiphysics to model subsurface fate and transport processes, (2) CFD0 to model atmospheric air flow around the building, and (3) CONTAM to model indoor air quality. The combined VI model predicts AER values, zonal indoor air pressures and zonal indoor air contaminant concentrations as a function of wind speed, wind direction and outdoor and indoor temperature. Steady state modeling results for a single-story building with a basement demonstrate that wind speed, wind direction and opening locations in a building play important roles in changing the AER, indoor air pressure, and indoor air contaminant concentration. Calculated indoor air pressures ranged from approximately -10 Pa to +4 Pa depending on weather conditions and building characteristics. AER values, mass entry rates and indoor air concentrations vary depending on weather conditions and building characteristics. The presented modeling approach can be used to investigate the relationship between building features, AER, building pressures, soil gas concentrations, indoor air concentrations and VI exposure risks.

Idioma originalEnglish
Páginas (desde-hasta)1594-1607
Número de páginas14
PublicaciónEnvironmental Sciences: Processes and Impacts
Volumen19
N.º12
DOI
EstadoPublished - dic 2017

Nota bibliográfica

Publisher Copyright:
© 2017 The Royal Society of Chemistry.

Financiación

The project described was supported by University of Kentucky Superfund Research Program from the National Institute of Environmental Health Sciences [Grant number P42ES007380] and by the National Science Foundation [Grant number 1452800]. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institute of Environmental Health Sciences, the National Institutes of Health or the National Science Foundation.

FinanciadoresNúmero del financiador
National Science Foundation Arctic Social Science Program1452800
National Institutes of Health (NIH)
National Institutes of Health/National Institute of Environmental Health SciencesP42ES007380
University of Kentucky
National Science Foundation Arctic Social Science Program

    ODS de las Naciones Unidas

    Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

    1. Good health and well being
      Good health and well being

    ASJC Scopus subject areas

    • Environmental Chemistry
    • Public Health, Environmental and Occupational Health
    • Management, Monitoring, Policy and Law

    Huella

    Profundice en los temas de investigación de 'Three-dimensional vapor intrusion modeling approach that combines wind and stack effects on indoor, atmospheric, and subsurface domains'. En conjunto forman una huella única.

    Citar esto