The dual-wavelength diffuse correlation spectroscopy (DCS) flow-oximeter is an emerging technique enabling simultaneous measurements of blood flow and blood oxygenation changes in deep tissues. High signal-to-noise ratio (SNR) is crucial when applying DCS technologies in the study of human tissues where the detected signals are usually very weak. In this study, single-mode, few-mode, and multimode fibers are compared to explore the possibility of improving the SNR of DCS flow-oximeter measurements. Experiments on liquid phantom solutions and in vivo muscle tissues show only slight improvements in flow measurements when using the fewmode fiber compared with using the single-mode fiber. However, light intensities detected by the few-mode and multimode fibers are increased, leading to significant SNR improvements in detections of phantom optical property and tissue blood oxygenation. The outcomes from this study provide useful guidance for the selection of optical fibers to improve DCS flow-oximeter measurements.

Idioma originalEnglish
Número de artículo037001
PublicaciónJournal of Biomedical Optics
Volumen18
N.º3
DOI
EstadoPublished - mar 2013

Nota bibliográfica

Funding Information:
This study was supported partially by the grants R01 CA149274, R21 AR062356, and UL1RR033173 from National Institutes of Health (NIH). The content is solely the responsibility of the authors and does not necessarily represent the official views of NIH.

Financiación

This study was supported partially by the grants R01 CA149274, R21 AR062356, and UL1RR033173 from National Institutes of Health (NIH). The content is solely the responsibility of the authors and does not necessarily represent the official views of NIH.

FinanciadoresNúmero del financiador
National Institutes of Health (NIH)
National Center for Advancing Translational Sciences (NCATS)UL1TR000117
National Center for Advancing Translational Sciences (NCATS)

    ASJC Scopus subject areas

    • Electronic, Optical and Magnetic Materials
    • Biomaterials
    • Atomic and Molecular Physics, and Optics
    • Biomedical Engineering

    Huella

    Profundice en los temas de investigación de 'Using optical fibers with different modes to improve the signal-to-noise ratio of diffuse correlation spectroscopy flow-oximeter measurements'. En conjunto forman una huella única.

    Citar esto