Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Validation of tablet-based evaluation of color fundus images

  • Mark Christopher
  • , Daniela C. Moga
  • , Stephen R. Russell
  • , James C. Folk
  • , Todd Scheetz
  • , Michael D. Abràmoff

Producción científica: Articlerevisión exhaustiva

15 Citas (Scopus)

Resumen

Purpose: To compare diabetic retinopathy (DR) referral recommendations made by viewing fundus images using a tablet computer with those made using a standard desktop display. Methods: A tablet computer (iPad) and a desktop computer with a high-definition color display were compared. For each platform, 2 retinal specialists independently rated 1,200 color fundus images from patients at risk for DR using an annotation program Truthseeker. The specialists determined whether each image had referable DR and also how urgently each patient should be referred for medical examination. Graders viewed and rated the randomly presented images independently and were masked to their ratings on the alternative platform. Tablet-based and desktop display-based referral ratings were compared using cross-platform intraobserver kappa as the primary outcome measure. Additionally, interobserver kappa, sensitivity, specificity, and area under the receiver operating characteristic were determined. Results: A high level of cross-platform intraobserver agreement was found for the DR referral ratings between the platforms (κ = 0.778) and for the 2 graders (κ = 0.812). Interobserver agreement was similar for the 2 platforms (κ = 0.544 and κ = 0.625 for tablet and desktop, respectively). The tablet-based ratings achieved a sensitivity of 0.848, a specificity of 0.987, and an area under the receiver operating characteristic of 0.950 compared with desktop display-based ratings. Conclusion: In this pilot study, tablet-based rating of color fundus images for subjects at risk for DR was consistent with desktop display-based rating. These results indicate that tablet computers can be reliably used for clinical evaluation of fundus images for DR.

Idioma originalEnglish
Páginas (desde-hasta)1629-1635
Número de páginas7
PublicaciónRetina
Volumen32
N.º8
DOI
EstadoPublished - sept 2012

Financiación

FinanciadoresNúmero del financiador
National Eye Institute (NEI)R01EY018853

    ODS de las Naciones Unidas

    Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

    1. Good health and well being
      Good health and well being

    ASJC Scopus subject areas

    • Ophthalmology

    Huella

    Profundice en los temas de investigación de 'Validation of tablet-based evaluation of color fundus images'. En conjunto forman una huella única.

    Citar esto