Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death: A Systematic Review and Meta-Analysis

  • Ahmad Masri
  • , Ahmed M. Altibi
  • , Sebhat Erqou
  • , Mohammad A. Zmaili
  • , Ala Saleh
  • , Raed Al-Adham
  • , Karam Ayoub
  • , Moaaz Baghal
  • , Laith Alkukhun
  • , Amr F. Barakat
  • , Sandeep Jain
  • , Samir Saba
  • , Evan Adelstein

Producción científica: Article › revisión exhaustiva

61 Citas (Scopus)

Resumen

Objectives: This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD). Background: Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only. Methods: We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Laird's method. Results: Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I 2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I 2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I 2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I 2 = 94%). Conclusions: The rate of appropriately treated WCD patients over 3 months of follow-up was substantial; higher in-observational studies as compared with the VEST trial. There was significant heterogeneity. More RCTs are needed to justify continued use of WCD in primary prevention.

Idioma originalEnglish
Páginas (desde-hasta)152-161
Número de páginas10
PublicaciónJACC: Clinical Electrophysiology
Volumen5
N.º2
DOI
EstadoPublished - feb 2019

Nota bibliográfica

Publisher Copyright:
© 2019 American College of Cardiology Foundation

Financiación

FinanciadoresNúmero del financiador
National Heart, Lung, and Blood Institute (NHLBI)T32HL129964

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine
    • Physiology (medical)

    Huella

    Profundice en los temas de investigación de 'Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death: A Systematic Review and Meta-Analysis'. En conjunto forman una huella única.

    Citar esto